Ductless 12000 Btuh 230V Heat Pump Single Zone Cassette System with Sensibo Wi-Fi Kit

Item: DoD-Bundle-10a
What’s the price?
Sign in for pricing.

About This Product

Product Info

Description

Ductless 12000 Btuh 230V Heat Pump Single Zone Cassette System with Sensibo Wi-Fi Kit

Specifications

BrandCarrier Enterprise

Bundle Components

Sensibo - SEN-INS-CAR-02 - Smart AC Module Compatible with Carrier MBC & MBF Cassette and Floor Units

Item: SEN-INS-CAR-02

Description

Sensibo - SEN-INS-CAR-02 Module for Carrier MBC & MBF Cassette and Floor units

Sensibo is a smart air conditioner module that connects Carrier and Bryant Ductless systems to WiFi and the internet for complete control on the go. Customers can control their air conditioners from their smartphones using the Sensibo app. One kit is required per indoor unit, making it usable in both Single and Multi Zone applications.

Features:
  • Using your location, the system can turn on automatically before you arrive home and turn off after you leave
  • Also compatible with voice assistance, such as Amazon Echo (Alexa), Google Assistant, Google Home and others
  • Installs and sets up in minutes
  • Saves energy through scheduling, automation and filter cleaning alerts
Compatible Systems:
  • SEN-INS-CAR-805 Sensibo Inside WiFi for 40MAQ/619P Wall Units
  • SEN-INS-CAR-01 Sensibo Inside WiFi for 40MBD/619REQ*D Ducted Units
  • SEN-INS-CAR-02 Sensibo Inside WiFi for 40MBC/619REQ*C & 40MBF/619REQ*F Cassette & Floor Units

Specifications

Weight0.044 Pounds (lbs)
Width2.09 Inches (In)
Height0.55 Inches (In)
Country of OriginCHN
Length2.05 Inches (In)
BrandSensibo
ColorWhite
Prop 65No

40MBCQ12---3 - 12000 Btuh Ductless Heat Pump Cassette

Item: 40MBCQ12---3

Description

40MBCQ12---3
40 = Fan Coil Unit
MB = Model
C = Cassette - Indoor Fan Coil Type
Q = Heat Pump - System Type
12 = 1 Ton - Nominal Capacity
- = Not Used
-- = Not Used
3 = 208/230-1-60 - Voltage


FEATURES / BENEFITS
A PERFECT BALANCE BETWEEN BUDGET LIMITS, ENERGY SAVINGS AND COMFORT.
The 40MBCQ series ductless systems are a matched combination of an outdoor condensing unit and an indoor fan coil unit connected only by refrigerant tubing and wires.
The in-ceiling cassette fan coils are ideal for retrofit or modernization projects where a false ceiling is available. This selection of fan coils permits inexpensive and creative solutions to design problems such as:
  •  Add-ons to current space (an office or family room addition)
  •  Special space requirements
  •  When changes in the load cannot be handled by the existing system
  •  When adding air conditioning to spaces that are heated by hydronic or electric heat and have no ductwork
  •  Historical renovations or any application where preserving the look of the original structure is essential.
The ideal compliment to your ducted system when it is impractical or prohibitively expensive to use ductwork. These compact indoor fan coil units take up very little space in the room and do not obstruct windows. The fan coils are attractively styled to blend with most room decors.
Advanced system components incorporate innovative technology to provide reliable cooling performance at low sound levels.

LOW SOUND LEVELS
When noise is a concern, the ductless systems are the answer. The indoor units are whisper quiet. There are no compressors indoors, either in the conditioned space or directly over it, and there is none of the noise usually generated by air being forced through ductwork.
SECURE OPERATION
If security is an issue, outdoor and indoor units are connected only by refrigerant piping and wiring to prevent intruders from crawling through ductwork. In addition, since outdoor units can be installed close to an outside wall, coils are protected from vandals and severe weather.
FAST INSTALLATION
This compact ductless system is simple to install. A mounting bracket is standard with the indoor units and only wire and piping needs to run between indoor and outdoor units. These units are fast and easy to install ensuring minimal disruption to customers in the home or workplace. This makes the ductless systems the equipment of choice, especially in retrofit situations.
SIMPLE SERVICING AND MAINTENANCE
Removing the top panel on outdoor units provides immediate access to the control compartment, providing a service technician access to check unit operation. In addition, the draw-thru design of the outdoor section means that dirt accumulates on the outside surface of the coil. Coils can be cleaned quickly from inside using a pressure hose and detergent.
On all indoor units, service and maintenance expense is reduced due to easy-to-use cleanable filters. In addition, these cassette systems have extensive self-diagnostics to assist in troubleshooting.
BUILT-IN RELIABILITY
Ductless system indoor and outdoor units are designed to provide years of trouble-free operation.
The in-ceiling cassette units include protection against freeze-up and high evaporator temperatures on heat pumps.
The condensing units on heat pumps are protected by a three minute time delay before the compressor starts the over-current protection and the high temperature protection.
INDIVIDUAL ROOM COMFORT
Maximum comfort is provided because each space can be controlled individually based on usage pattern. The air sweep feature provided permits optimal room air mixing to eliminate hot and cold spots for occupant comfort. In addition, year-round comfort can be provided with heat pumps.
ECONOMICAL OPERATION
The ductless system design allows individual room heating or cooling when required. There is no need to run large supply-air fans or chilled water pumps to handle a few spaces with unique load patterns. In addition, because air is moved only in the space required, no energy is wasted moving air through ducts.
EASY-TO-USE CONTROLS
The in-ceiling cassette has microprocessor-based controls to provide the ultimate in comfort and efficiency. The user friendly wireless remote control provides the interface between user and the unit.
FACTORY INSTALLED CONDENSATE LIFT PUMP
Customizing these ductless systems to your application is easily accomplished. The factory installed condensate lift pump on the cassette fan coil unit provides installation flexibility.
OPTIONAL WIRED CONTROLLER
AGENCY LISTINGS

All systems are listed with AHRI (Air Conditioning, Heating & Refrigeration Institute), and ETL.

Specifications

Weight35.27 Pounds (lbs)
Width22.44 Inches (In)
Height10.24 Inches (In)
Country of OriginCHN
Length22.44 Inches (In)
Blower Motor HP61/1000 HP
Blower Motor RPM960
Blower Motor Speeds3
Blower Motor TypeFixed Torque
Blower Motor Watts0
Blower WheelNot Provided
BrandPayne,Carrier,Bryant
CertificationsAHRI Certified
CFM280-400
Circuit Breaker - Max Amps0
Circuit Breaker - Min Amps0
ColorWhite
Cooling Capacity12000
Cycle/Hertz60 Hz
Drain Connection Size1"
EER0
Liquid Line FittingFlare
Liquid Line Size1/4"
Maximum Fuse Size0
Maximum Piping LengthNot Provided
Minimum Circuit Amps0.2
PhaseSingle
Product Family40MBCQ
Prop 65Yes
Rated Current Amps0.146
Rated Load Amps0
RefrigerantR-410a
SEER0
StageNot Provided
Suction Line FittingFlare
Suction Line Size1/2"
TierPerformance,Preferred™
Tonnage1
Voltage208-230 VAC
Warranty OfferedYes

Ductless 12000 Btuh Heat Pump Single Zone w/ Basepan Heater 208/230-1

Item: 38MAQB12R--3

Description

38MAQB12R--3
38 = OUTDOOR UNIT
MA = MODEL
Q = HEAT PUMP SYSTEM TYPE
B = 1:1 MAXIMUM NUMBER OF FAN COIL UNITS THAT CAN BE CONNECTED TO THE OUTDOOR UNIT
12 = 1 TON NOMINAL CAPACITY
R = HIGH HEAT UNIT TYPE
-- = NOT USED
3 = 208/230-1-60

The 38MA*R series ductless split systems are a matched combination of an outdoor condensing unit and an indoor fan coil unit connected only by refrigerant tubing and wires.The ductless system permits creative solutions to design problems such as:

  • Add-ons to current space (an office or family room addition)
  • Special space requirements
  • When changes in the load cannot be handled by the existing system
  • When adding air conditioning to spaces that are heated by hydronic or electric heat and have no ductwork

Historical renovations or any application where preserving the look of the original structure is essential.The ideal compliment to your ducted system when it is impractical or prohibitively expensive to use ductwork. The compact indoor fan coil units take up very little space in the room and do not obstruct windows. The fan coils are attractively styled to blend with most room decors. Advanced system components incorporate innovative technology to provide reliable cooling performance at low sound levels.

LOW SOUND LEVELS
When noise is a concern, the ductless split systems are the answer.The indoor units are whisper quiet. There are no compressors indoors, either in the conditioned space or directly over it, and there is none of the noise usually generated by air being forced through ductwork.
When sound ordinances and proximity to neighbors demand quiet operation, the 38MA*R unit is the right choice. The advanced, horizontal airflow design distributes air more evenly over the coil.
SECURE OPERATION
If security is an issue, outdoor and indoor units are connected only by refrigerant piping and wiring to prevent intruders from crawling through ductwork. In addition, since 38MA*R units can be installed close to an outside wall, coils are protected from vandals and severe weather.
FAST INSTALLATION
This compact ductless split system is simple to install. A mounting bracket is standard with the indoor units and only wire and piping need to be run between the indoor and outdoor units (High Walls).These units are fast and easy to install ensuring minimal disruption to customers in the home or workplace. This makes the 38MA*R ductless split systems the equipment of choice, especially in retrofit situations.
SIMPLE SERVICING AND MAINTENANCE
Removing the top panel on outdoor units provides immediate access to the control compartment, providing a service technician access to check unit operation. In addition, the draw-thru design of the outdoor section means that dirt accumulates on the outside surface of the coil. Coils can be cleaned quickly from the inside using a pressure hose and detergent.
On all indoor units, service and maintenance expense is reduced due to easy-to-use cleanable filters. In addition, these systems have extensive self-diagnostics to assist in troubleshooting.
BUILT-IN RELIABILITY
Ductless split system indoor and outdoor units are designed to provide years of trouble-free operation.
The indoor units include protection against freeze-up and high evaporator temperatures on heat pumps.
The condensing units on heat pumps are protected by a three minute time delay before the compressor starts the over-currentprotection and the high temperature protection.
INDIVIDUAL ROOM COMFORT
Maximum comfort is provided because each space can be controlled individually based on usage pattern. The air sweep (in some indoor models) feature provided permits optimal room air mixing to eliminate hot and cold spots for occupant comfort. In addition, year-round comfort can be provided with heat pumps.
ECONOMICAL OPERATION
The ductless split system design allows individual room heating or cooling when required. There is no need to run large supply-airfans or chilled water pumps to handle a few spaces with unique load patterns. In addition, because air is moved only in the space required, no energy is wasted while air moves through the ducts.
EASY-TO-USE CONTROLS
The indoor units have microprocessor-based controls to provide the ultimate in comfort and efficiency. The user friendly wireless remote control provides the interface between the user and the unit.
ACCESSORIES
Customizing these ductless split systems to your application is easily accomplished. Adding a condensate pump accessory to the indoor fan coil provides installation flexibility.
OPTIONAL WIRED CONTROLLER
AGENCY LISTINGS
All systems are listed with AHRI (Air Conditioning, Heating & Refrigeration Institute), and ETL.

Specifications

Weight91.5 Pounds (lbs)
Width32.09 Inches (In)
Height21.81 Inches (In)
Country of OriginCHN
Length13.11 Inches (In)
BrandBryant,Carrier
CertificationsAHRI Certified
CFM1200
Circuit Breaker - Max Amps15
Circuit Breaker - Min Amps0
ColorGray
Condenser Motor HP1/20 HP
Condenser Motor RPM900
Condenser Motor TypeDirect Drive
Cooling Capacity12000
Cooling Rated Capacity Btu/h12000
Cycle/Hertz60 Hz
EER12.5
Heating Capacity12000
HSPF12
InverterYes
Liquid Line FittingFlare
Liquid Line Size1/4"
Maximum Fuse Size15
Maximum Piping Length82'
Minimum Circuit Amps9
Nominal EER12
Number of HVAC Zones1
PhaseSingle
Product Family38MAR
Prop 65Yes
Rated Current Amps5.7
Rated Load Amps5.7
RefrigerantR-410a
SEER22
Sound Level (dBA)56
StageVariable
Suction Line FittingFlare
Suction Line Size1/2"
TierPerformance,Preferred™
Tonnage1
Voltage208-230 VAC
Warranty OfferedYes
Zone Capability1 Zone

Equipment Part List

Loading...
*No Purchase Necessary - CE Southeast MR45 Recovery Machine Giveaway Official Rules and Conditions